ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition

ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
分享
扫描下方二维码分享到微信
打开微信,点击右上角”+“,
使用”扫一扫“即可将网页分享到朋友圈。
作者:
出版社: JohnWiley
2010-06
ISBN: 9781444324266
定价: 426.80
装帧: 平装
页数: 202页
正文语种: 英语
  • Manual calculations are still extensively used and in particular are necessary for checking and verifying various software calculation design packages. It is highly recommended that users of such software familiarise themselves with the rudiments of these calculations prior to using the software packages.This essential book fills the gap between software and manual calculations. It provides the reader with all the necessary tools to enable accurate calculations of circuit designs. Rather than complex equations, this book uses extensive worked examples to make understanding the calculations simpler. The focus on worked examples furnishes the reader with the knowledge to carry out the necessary checks to electrical cable sizing software programmes.Other key features include:Updated information on 230 volt references and voltage drop under normal load conditions New sections on buried cables that take into account soil thermal conductivity, trenches and grouping, allowing readers to carry out accurate cables sizing Information and examples of steel wired armour cables, new to this edition. This includes sufficiency during short circuits and, for cables with externally run CPCs, gives unique fault conditions. Covers calculations of cross–sectional areas of circuit live conductors Earth fault loop impedances Protective conductor cross–sectional areas and short circuit conditions Short circuit protection. The last chapter combines all of the calculations of the previous chapters to enable the reader to complete an accurate design of an installation circuit under all conditions.A unique tool for detailed electrical installation trade, Electrical Installation Calculations, Fourth Edition is invaluable to electricians, electrical designers, installers, technicians, contractors, and plant engineers. Senior electrical engineering students and technical colleges, junior engineers, and contracts managers will also find this text useful. Scott Deming is an international speaker, trainer, and business consultant who delivers high-energy sales and customer service presentations and seminars to associations and corporations across the globe, over 100 times a year. He formerly ran his own national marketing and advertising firm, RCI, which he grew into a multimillion-dollar business. About the Authors.   Preface.   Acknowledgements.   Symbols.   Definitions.   1 Calculation of the cross-sectional areas of circuit live conductors.   General circuits.   Circuits in thermally insulating walls.   Circuits totally surrounded by thermally insulating material.   Circuits in varying external influences and installation conditions.   Circuits in ventilated trenches.   Circuits using mineral-insulated cables.   Circuits on perforated metal cable trays.   Circuits in enclosed trenches.   Circuits buried in the ground.   Grouped circuits not liable to simultaneous overload.   Circuits in low ambient temperatures.   Grouped ring circuits.   Motor circuits subject to frequent stopping and starting.   Circuits for star-delta starting of motors.   Change of parameters of already installed circuits.   Admixtures of cable sizes in enclosures.   Grouping of cables having different insulation.   2 Calculation of voltage drop under normal load conditions.   The simple approach.   The more accurate approach taking account of conductor operating temperature.   The more accurate approach taking account of load power factor.   The more accurate approach taking account of both conductor operating temperature and load power factor.   Voltage drop in ring circuits.   Voltage drop in ELV circuits.   3 Calculation of earth fault loop impedance.   The simple approach.   The more accurate approach taking account of conductor temperature.   Calculations taking account of transformer impedance.   Calculations concerning circuits fed from sub-distribution boards.   Calculations where conduit or trunking is used as the protective conductor.   Calculations where cable armouring is used as the protective conductor.   4 Calculations concerning protective conductor cross-sectional areas.   Calculations when the protective device is a fuse.   Calculations when an external cpc is in parallel with the armour.?  Calculations when the protective device is an mcb.   Calculations when the protective device is an RCD or RCBO.   5 Calculations related to short circuit conditions.   a. c. single-phase circuits.   The more rigorous method for A.C. single-phase circuits.   a.c. three-phase circuits.   6 Combined examples.   Appendix The touch voltage concept.   Index.
  • 内容简介:
    Manual calculations are still extensively used and in particular are necessary for checking and verifying various software calculation design packages. It is highly recommended that users of such software familiarise themselves with the rudiments of these calculations prior to using the software packages.This essential book fills the gap between software and manual calculations. It provides the reader with all the necessary tools to enable accurate calculations of circuit designs. Rather than complex equations, this book uses extensive worked examples to make understanding the calculations simpler. The focus on worked examples furnishes the reader with the knowledge to carry out the necessary checks to electrical cable sizing software programmes.Other key features include:Updated information on 230 volt references and voltage drop under normal load conditions New sections on buried cables that take into account soil thermal conductivity, trenches and grouping, allowing readers to carry out accurate cables sizing Information and examples of steel wired armour cables, new to this edition. This includes sufficiency during short circuits and, for cables with externally run CPCs, gives unique fault conditions. Covers calculations of cross–sectional areas of circuit live conductors Earth fault loop impedances Protective conductor cross–sectional areas and short circuit conditions Short circuit protection. The last chapter combines all of the calculations of the previous chapters to enable the reader to complete an accurate design of an installation circuit under all conditions.A unique tool for detailed electrical installation trade, Electrical Installation Calculations, Fourth Edition is invaluable to electricians, electrical designers, installers, technicians, contractors, and plant engineers. Senior electrical engineering students and technical colleges, junior engineers, and contracts managers will also find this text useful.
  • 作者简介:
    Scott Deming is an international speaker, trainer, and business consultant who delivers high-energy sales and customer service presentations and seminars to associations and corporations across the globe, over 100 times a year. He formerly ran his own national marketing and advertising firm, RCI, which he grew into a multimillion-dollar business.
  • 目录:
    About the Authors.   Preface.   Acknowledgements.   Symbols.   Definitions.   1 Calculation of the cross-sectional areas of circuit live conductors.   General circuits.   Circuits in thermally insulating walls.   Circuits totally surrounded by thermally insulating material.   Circuits in varying external influences and installation conditions.   Circuits in ventilated trenches.   Circuits using mineral-insulated cables.   Circuits on perforated metal cable trays.   Circuits in enclosed trenches.   Circuits buried in the ground.   Grouped circuits not liable to simultaneous overload.   Circuits in low ambient temperatures.   Grouped ring circuits.   Motor circuits subject to frequent stopping and starting.   Circuits for star-delta starting of motors.   Change of parameters of already installed circuits.   Admixtures of cable sizes in enclosures.   Grouping of cables having different insulation.   2 Calculation of voltage drop under normal load conditions.   The simple approach.   The more accurate approach taking account of conductor operating temperature.   The more accurate approach taking account of load power factor.   The more accurate approach taking account of both conductor operating temperature and load power factor.   Voltage drop in ring circuits.   Voltage drop in ELV circuits.   3 Calculation of earth fault loop impedance.   The simple approach.   The more accurate approach taking account of conductor temperature.   Calculations taking account of transformer impedance.   Calculations concerning circuits fed from sub-distribution boards.   Calculations where conduit or trunking is used as the protective conductor.   Calculations where cable armouring is used as the protective conductor.   4 Calculations concerning protective conductor cross-sectional areas.   Calculations when the protective device is a fuse.   Calculations when an external cpc is in parallel with the armour.?  Calculations when the protective device is an mcb.   Calculations when the protective device is an RCD or RCBO.   5 Calculations related to short circuit conditions.   a. c. single-phase circuits.   The more rigorous method for A.C. single-phase circuits.   a.c. three-phase circuits.   6 Combined examples.   Appendix The touch voltage concept.   Index.
查看详情
目前没有书店销售此书
相关图书 / 更多
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
世上为什么要有图书馆
杨素秋
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
经纬度丛书·大变局:晚清改革五十年
谌旭彬
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
拓地降敌:北宋中叶内臣名将李宪研究
何冠环
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
班史:一个大学班级的日常生活(2018—2022)
黄修志 石榴花 著
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
另一场新文化运动:五四前后“梁启超系”再造新文明的努力
周月峰 著
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
无条件投降博物馆
[荷兰]杜布拉夫卡·乌格雷西奇
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
我们为什么会抑郁:哀悼、忧郁与精神分析
达里安·利德
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
被遗忘的大流行:西班牙流感在美国
艾尔弗雷德·W. 克罗斯比 著;李玮璐 译
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
辛弃疾新传
辛更儒 后浪
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
疯狂的尿酸
[美]戴维·珀尔马特 著
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
中国妆束:宋时天气宋时衣
左丘萌 末春
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
阿勒泰的角落
李娟 著;新经典 出品
您可能感兴趣 / 更多
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
家长的思维模式:儿童成长型思维模式的培养策略
Mary;Cay;Ricci
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
印度洋明珠:毛里求斯商贸要略
Marie Lourdes Lam Hung(玛丽·卢尔德·林·洪)
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
自然象征——宇宙论的探索(汉译人类学名著丛书)
Mary Douglas
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
欧盟个人数据保护制度——《一般数据保护条例》
Mariusz Krzysztofek
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
巴西小史
Maria del Priore
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
世界啤酒地图:150种啤酒大赏
Mark Dredge
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
法理学和政治学中的自然法(自然法名著译丛)
Mark C. Murphy
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
数学天书中的证明(第六版)
Martin Aigner;Günte
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
机器学习Python版(英文版)
Mark E. Fenner
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
关于《马丁·菲耶罗》
Margarita Guerrero 著;赵振江 译;豪尔赫·路易斯·博尔赫斯;玛加丽塔·格雷罗(Jorge Luis Borges
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
日耳曼中世纪文学
María Esther Vázquez 著;崔燕 译;豪尔赫·路易斯·博尔赫斯 玛丽亚·埃丝特·巴斯克斯(Jorge Luis Borges
ElectricalInstallationCalculations:ForCompliancewithBS7671:2008,4thEdition
幕后
Mary Ellen Mark